44CHAPTER 3: SYSTEM SERVICE COMMANDS

Table 7 display system output (continued)

Field

Description

 

 

Temperature

Status of temperature sensors at three locations in the WX

 

switch:

 

„ ok — Temperature is within the acceptable range of

 

0° C to 50° C (32° F to 122° F).

 

„ Alarm — Temperature is above or below the

 

acceptable range. MSS sends an alert to the system log

 

every 5 minutes until this condition is corrected.

 

 

PSU Status

Status of the lower and upper power supply units:

 

„ missing — Power supply is not installed or is

 

inoperable.

 

„ DC ok — Power supply is producing DC power.

 

„ DC output failure — Power supply is not producing

 

DC power. MSS sends an alert to the system log every

 

5 minutes until this condition is corrected.

 

„ AC ok — Power supply is receiving AC power.

 

„ AC not present — Power supply is not receiving AC

 

power.

 

 

Memory

Current size (in megabytes) of nonvolatile memory

 

(NVRAM) and synchronous dynamic RAM (SDRAM), plus

 

the percentage of total memory space in use, in the

 

following format:

 

NVRAM size /SDRAM size (percent of total)

 

 

Total Power Over

Total power that the device is currently supplying to its

Ethernet

directly connected MAP access points, in watts.

 

 

See Also

„clear system on page 39

„set system contact on page 51

„set system countrycode on page 51

„set system ip-addresson page 53

„set system location on page 54

„set system name on page 55