Chapter 10 Configuring Ethernet OAM

 

Command

Purpose

Step 9

 

 

ethernet oam link-monitor receive-crc {threshold

(Optional) Configure thresholds for monitoring ingress

 

{high {high-frames none} low {low-frames}}

frames received with cyclic redundancy code (CRC) errors

 

window milliseconds}

for a period of time.

 

Note Repeat this step to configure both high and

Enter threshold high high-framesto set a high

 

low thresholds.

threshold for the number of frames received with CRC

 

 

errors. The range is 1 to 65535 frames.

 

 

Enter threshold high none to disable the high

 

 

threshold.

 

 

Enter threshold low low-framesto set a low threshold

 

 

in number of frames. The range is 0 to 65535. The

 

 

default is 1.

 

 

Enter window milliseconds to set the a window and

 

 

period of time during which frames with CRC errors

 

 

are counted. The range is 10 to 1800 and represents the

 

 

number of milliseconds in multiples of 100. The

 

 

default is 100.

Step 10

 

 

ethernet oam link-monitor transmit-crc {threshold

Use the ethernet oam link-monitor transmit-crc

 

{high {high-frames none} low low-frames}

command to configure an Ethernet OAM interface to

 

window milliseconds} }

monitor egress frames with CRC errors for a period of

 

 

time.

Step 11

 

 

[no] ethernet link-monitor on

(Optional) Start or stop (when the no keyword is entered)

 

 

link-monitoring operations on the interface. Link

 

 

monitoring operations start automatically when support is

 

 

enabled.

Step 12

 

 

end

Return to privileged EXEC mode.

Step 13

 

 

show ethernet oam status [interface interface-id]

Verify the configuration.

Step 14

 

 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

 

 

 

The ethernet oam link-monitor transmit-crc {threshold {high {high-framesnone} low

{low-frames}} window milliseconds} command is visible on the router and you are allowed to enter it, but it is not supported. Use the no form of this commands to disable the configuration. Use the no form of each command to disable the threshold setting.

Configuring Ethernet OAM Remote Failure Indications

You can configure an error-disable action to occur on an interface if one of the high thresholds is exceeded, if the remote link goes down, if the remote device is rebooted, if the remote device disables Ethernet OAM on the interface, or if the power failure occurs on the remote device .

Complete the following steps to enable Ethernet OAM remote-failure indication actions on an interface:

 

 

Command

 

Purpose

 

Step 1

 

 

 

 

configure terminal

 

Enter global configuration mode.

 

Step 2

 

 

 

 

interface interface-id

 

Define an interface, and enter interface configuration

 

 

 

 

mode.

 

 

 

 

 

 

 

 

 

 