Chapter 2 Licensing

Port or Interface Behavior

Router# show ip interface brief

 

 

 

Interface

IP-Address

OK? Method

Status

Protocol

GigabitEthernet0/0

unassigned

YES unset

administratively down down

GigabitEthernet0/1

unassigned

YES unset

administratively down down

GigabitEthernet0/2

unassigned

YES unset

administratively down down

GigabitEthernet0/3

unassigned

YES unset

administratively down down

GigabitEthernet0/4

unassigned

YES unset

down

down

GigabitEthernet0/5

unassigned

YES unset

down

down

GigabitEthernet0/6

unassigned

YES unset

down

down

GigabitEthernet0/7

unassigned

YES unset

down

down

GigabitEthernet0/8

unassigned

YES unset

administratively down down

GigabitEthernet0/9

unassigned

YES unset

administratively down down

GigabitEthernet0/10

unassigned

YES unset

administratively down down

GigabitEthernet0/11

unassigned

YES unset

administratively down down

FastEthernet0/0

unassigned

YES NVRAM

administratively down down

Vlan1

unassigned

YES unset

down

down

Example: When Flexi License is Installed

Following is a sample output from the show license command:

Router#

show license

Index 1

Feature: AdvancedMetroIPAccess

 

Period left: Life time

 

License Type: Permanent

 

License State: Active, In Use

 

License Count: Non-Counted

 

License Priority: Medium

Index 2

Feature: IPBase

Index 3

Feature: Gige4portflexi

1588BC License

When the SL-A901-T 1588BC license is not installed, the PTP boundary clock cannot be configured. For more information on configuring the PTP boundary clock, see PTP Boundary Clock.

Example: When 1588BC License is not Installed

The following error message appears on configuring the PTP boundary clock, when the 1588BC license is not installed:

Note Though an error message appears on configuring the PTP boundary clock, the running-config file accepts the PTP boundary clock configuration. This configuration can be saved. However, the PTP boundary clock is not configured in the hardware, and is inactive.

Router(config)# ptp clock boundary domain 0

%ERROR: Boundary Clock needs a separate license. Please install license and reconfigure

PTP.

Router(config-ptp-clk)#

Example: When 1588BC License is Installed

The following example shows how to install the 1588BC license:

Router# license install flash:CAT1632U029_20121005013805577.lic

Cisco ASR 901 Series Aggregation Services Router Software Configuration Guide

 