Chapter 31 Microwave ACM Signaling and EEM Integration

How to Configure Microwave ACM Signaling and EEM Integration

Configuring EEP Applet Using CLIs

To configure EEP applet, complete the following steps:

Prerequisites

One switch virtual interface (SVI) or bridge domain is required per physical link.

One EEM script is required per physical link.

Note The EEM script configures the metric on the microwave link and adjusts the QoS policy based on the Ethernet event parameters. You can download the scripts from the following location:

SUMMARY STEPS

1.enable

2.configure terminal

3.event manager applet applet-name

4.event tag event-tagethernet microwave clear-sd {interface type number}

5.event tag event-tagethernet microwave sd {interface type number} threshold mbps

6.action action-id set variable-name variable-value

7.action action-id cli command cli-string

8.action action-id cli command cli-string

9.exit

DETAILED STEPS

 

Command

Purpose

 

 

 

Step 1

enable

Enables privileged EXEC mode.

 

 

Enter your password if prompted.

 

Example:

 

 

Router> enable

 

 

 

 

Step 2

configure terminal

Enters global configuration mode.

 

Example:

 

 

Router# configure terminal

 

 

 

 

Step 3

event manager applet applet-name

Registers an applet with the Embedded Event Manager (EEM) and

 

 

enters applet configuration mode.

 

Example:

applet-name—Name of the applet file.

 

Router(config)# event manager applet

 

 

ACM61

 

 

 

 

 

 

Cisco ASR 901 Series Aggregation Services Router Software Configuration Guide

 

 

 

 

 

 

OL-23826-09

 

 

31-7

 

 

 

 

 

Page 593