Cisco Systems A9014CFD manual Configuring CFM over EFP Interface with Cross Connect, 10-20

Models: A9014CFD

1 884
Download 884 pages 9.83 Kb
Page 190
Image 190

Chapter 10 Configuring Ethernet OAM

Receive CFM messages from the core.

Forward CFM messages to the access side (after Continuity Check Database [CCDB] based on maintenance point [MP] filtering rules).

This section contains the following topics:

Configuring CFM over EFP Interface with Cross Connect, page 10-20

Configuring CFM over EFP Interface with Cross Connect—PortChannel-Based Cross Connect Tunnel, page 10-22

Configuring CFM over EFP Interface with Cross Connect

To configure CFM over EFP Interface with cross connect, complete the following steps.

 

Command

Purpose

 

 

 

Step 1

enable

Enables privileged EXEC mode.

 

 

Enter your password if prompted.

 

Example:

 

 

Router# enable

 

 

 

 

Step 2

configure terminal

Enters global configuration mode.

 

Example:

 

 

Router# configure terminal

 

 

 

 

Step 3

pseudowire-class [pw-class-name]

Specifies the name of a Layer 2 pseudowire class and

 

 

enter pseudowire class configuration mode.

 

Example:

 

 

Router(config)# pseudowire-class

 

 

vlan-xconnect

 

 

 

 

Step 4

encapsulation mpls

Specifies that Multiprotocol Label Switching (MPLS) is

 

 

used as the data encapsulation method for tunneling

 

Example:

Layer 2 traffic over the pseudowire.

 

 

 

Router(config-if)# encapsulation mpls

 

 

 

 

Step 5

exit

Exits the pseudowire class configuration mode.

 

Example:

 

 

Router(config-if-srv)# exit

 

 

 

 

Step 6

interface gigabitethernet slot/port or

Specifies the Gigabit Ethernet or the Ten Gigabit

 

interface tengigabitethernet slot/port

Ethernet interface to configure.

 

Example:

 

 

Router(config-if-srv)# interface

 

 

Gi2/0/2

 

 

 

 

 

Cisco ASR 901 Series Aggregation Services Router Software Configuration Guide

10-20