10-22

Cisco ASR 901 Series Aggregation Services Router Software Configuration Guide
OL-23826-09
Chapter 10 Configuring Ethernet OAM
ASR901(config-if-srv)#encapsulation untagged
ASR901(config-if-srv)# xconnect 3.3.3.3 3 encapsulation mpls
ASR901(cfg-if-ether-vc-xconn)# mtu 1500
ASR901(cfg-if-ether-vc-xconn)# cfm mep domain L5 mpid 511
Example for single tag Encapsulation
ASR901(config)#int g0/1
ASR901(config-if)#service instance 711 ethernet e711
ASR901(config-if-srv)# encapsulation dot1q 711
ASR901(config-if-srv)# xconnect 3.3.3.3 3 encapsulation mpls
ASR901(cfg-if-ether-vc-xconn)# mtu 1500
ASR901(cfg-if-ether-vc-xconn)# cfm mep domain L5 mpid 511

Configuring CFM over EFP Interface with Cross Connect—Port Channel-Based Cross Connect

Tunnel

This section describes how to configure CFM over EFP Interface with Port Channel-Based cross connect

Tunnel.

Examples

This example shows how to configure CFM over EFP Interface with Port Channel-Based cross connect

Tunnel:

ASR901(config)#ethernet cfm ieee
ASR901(config)#ethernet cfm global
ASR901(config)#ethernet cfm domain L5 level 5
ASR901(config-ecfm)# service s1 evc e711
ASR901(config-ecfm-srv)# continuity-check
ASR901(config-ecfm-srv)#exit
ASR901(config-ecfm)#exit
ASR901(config)#interface GigabitEthernet0/1
ASR901(config-if)# negotiation auto
ASR901(config-if)# no keepalive
ASR901(config-if)# channel-group 1 mode on
ASR901(config-if)#exit
ASR901(config)#interface GigabitEthernet0/7
ASR901(config-if)# negotiation auto
ASR901(config-if)# channel-group 1 mode on
ASR901(config-if)#exit
ASR901(config)#int port-channel 1
ASR901(config-if)#service instance 711 ethernet e711
ASR901(config-if-srv)# encapsulation dot1q 711
ASR901(config-if-srv)# xconnect 3.3.3.3 3 encapsulation mpls
ASR901(cfg-if-ether-vc-xconn)# mtu 1500
ASR901(cfg-if-ether-vc-xconn)# cfm mep domain L5 mpid 511
Verification

Use the following commands to verify a configuration:

•Use the show ethernet cfm maintenance-point local commands to verify the CFM over EVC

configuration. This command shows the basic configuration information for CFM.

Router-30-PE1#show ethernet cfm maintenance-point local
Local MEPs:
--------------------------------------------------------------------------------
MPID Domain Name Lvl MacAddress Type CC