Chapter 31 Microwave ACM Signaling and EEM Integration

How to Configure Microwave ACM Signaling and EEM Integration

How to Configure Microwave ACM Signaling and EEM Integration

This section describes how to configure Microwave ACM Signaling and EEM Integration:

Configuring Connectivity Fault Management, page 31-4(Required)

Configuring EEP Applet Using CLIs, page 31-7(Required)

Configuring Event Handler, page 31-9(Required)

Verifying Microwave Microwave ACM Signaling and EEM Integration Configuration, page 31-10(Optional)

Configuring Connectivity Fault Management

To configure CFM between the microwave outdoor unit (ODU) and the router, complete the following steps:

Note For a ring topology, you should configure CFM between the microwave ODU and the router. You must configure two VLANs to the two microwave ODUs, to process the vendor specific message (VSM) and trigger the Embedded Event Manager (EEM).

SUMMARY STEPS

1.enable

2.configure terminal

3.ethernet cfm domain domain-namelevel level-id

4.service csi-idevc evc-namevlan vlan-iddirection down

5.continuity-check

6.exit

7.ethernet evc evc-no

8.exit

9.interface type number

10.service instance id ethernet id

11.encapsulation dot1q vlan-id

12.rewrite ingress tag pop 1 symmetric

13.bridge-domainbridge-domain-id

14.exit

 

Cisco ASR 901 Series Aggregation Services Router Software Configuration Guide