Chapter 11 ITU-T Y.1731 Performance Monitoring

How to Configure ITU-T Y.1731 Performance Monitoring

 

Command

Purpose

 

 

 

Step 15 ip sla reaction-configuration operation-number

(Optional) Configures proactive threshold

 

[react {unavailableDS unavailableSD loss-ratioDS

monitoring for frame loss measurements.

 

loss-ratioSD}][threshold-type {average

operation-number—Identifies the IP SLAs

 

[number-of-measurements] consecutive [occurrences]

 

immediate}] [threshold-value upper-threshold

operation for which reactions are to be

 

lower-threshold]

configured.

 

 

 

Example:

react—(Optional) Specifies the element to be

 

monitored for threshold violations.

 

Router(config)# ip sla reaction-configuration 11

unavailableDS—Specifies that a reaction should

 

react unavailableDS

 

 

occur if the percentage of destination-to-source

 

 

Frame Loss Ratio (FLR) violates the upper

 

 

threshold or lower threshold.

 

 

unavailableSD—Specifies that a reaction should

 

 

occur if the percentage of source-to-destination

 

 

FLR violates the upper threshold or lower

 

 

threshold.

 

 

loss-ratioDS—Specifies that a reaction should

 

 

occur if the one-way destination-to-source

 

 

loss-ratio violates the upper threshold or lower

 

 

threshold.

 

 

loss-ratioSD—Specifies that a reaction should

 

 

occur if the one way source-to-destination

 

 

loss-ratio violates the upper threshold or lower

 

 

threshold.

 

 

threshold-type average

 

 

[number-of-measurements]—(Optional) When

 

 

the average of a specified number of

 

 

measurements for the monitored element exceeds

 

 

the upper threshold or when the average of a

 

 

specified number of measurements for the

 

 

monitored element drops below the lower

 

 

threshold, perform the action defined by the

 

 

action-typekeyword. The default number of 5

 

 

averaged measurements can be changed using the

 

 

number-of-measurements argument. The range is

 

 

from 1 to 16.

 

 

threshold-type consecutive

 

 

[occurrences]—(Optional) When a threshold

 

 

violation for the monitored element is met

 

 

consecutively for a specified number of times,

 

 

perform the action defined by the action-type

 

 

keyword.The default number of 5 consecutive

 

 

occurrences can be changed using the

 

 

occurrences argument. The range is from 1 to 16.

 

 

 

 

 