Chapter 30 Bit Error Rate Testing

How to Configure BERT

Terminating BERT on a T1/E1 Controller, page 30-3(Required)

Verifying BERT on a T1/E1 Controller, page 30-4(Optional)

Performing BERT on a T1/E1 Line

To enable BERT pattern on a T1 or E1 controller, perform the following steps.

SUMMARY STEPS

1.enable

2.configure terminal

3.controller {t1 e1} slot/port

4.bert pattern pattern interval time

DETAILED STEPS

 

Command

Purpose

 

 

 

Step 1

enable

Enables privileged EXEC mode.

 

 

Enter your password if prompted.

 

Example:

 

 

Router> enable

 

 

 

 

Step 2

configure terminal

Enters global configuration mode.

 

Example:

 

 

Router# configure terminal

 

 

 

 

Step 3

controller {t1 e1} slot/port

Selects a T1 or E1 controller and enters controller configuration

 

 

mode.

 

Example:

 

 

Router(config)# controller T1 0/5

 

 

 

 

Step 4

bert pattern pattern interval time

Sends a BERT pattern through the T1 or E1 line for the specified

 

 

time interval.

 

Example:

pattern—Length of the repeating BERT test pattern. See

 

Router(config-controller)# bert pattern 0s

Table 30-1for allowed values.

 

interval 30

interval—Specifies the duration of the BERT test, in minutes.

 

 

 

 

The interval can be a value from 1 to 14400.

 

 

 

Terminating BERT on a T1/E1 Controller

SUMMARY STEPS

1.enable

2.configure terminal

3.controller {t1 e1} slot/port

 

 

Cisco ASR 901 Series Aggregation Services Router Software Configuration Guide

 

 

 

 

 

 

OL-23826-09

 

 

30-3

 

 

 

 

 

Page 581
Image 581
Cisco Systems A9014CFD manual Performing Bert on a T1/E1 Line, Terminating Bert on a T1/E1 Controller, 30-3