xStack
config system_severity
Purpose | To configure when and where severity messages are to be |
| recorded. |
Syntax | config system_severity [trap log all] [critical warning |
| information] |
Description | This command is used to configure the system severity levels on the |
| Switch. When an event occurs on the Switch, a message will be sent |
| to the SNMP agent (trap), the Switch’s log or both. Events occurring |
| on the Switch are separated into three main categories. |
| • Information – Events classified as information are basic events |
| occurring on the Switch that are not deemed as problematic, |
| such as enabling or disabling various functions on the Switch. |
| • Warning - Events classified as warning are problematic events |
| that are not critical to the overall function of the Switch but do |
| require attention, such as unsuccessful downloads or uploads |
| and failed logins. |
| • Critical – Events classified as critical are fatal exceptions |
| occurring on the Switch, such as hardware failures or spoofing |
| attacks. |
Parameters | Choose one of the following to identify where severity messages are |
| to be sent. |
| • trap – Entering this parameter will define which events |
| occurring on the Switch will be sent to a SNMP agent for |
| analysis. |
| • log – Entering this parameter will define which events |
| occurring on the Switch will be sent to the Switch’s log for |
| analysis. |
| • all – Entering this parameter will define which events occurring |
| on the Switch will be sent to a SNMP agent and the Switch’s |
| log for analysis. |
| Choose one of the following to identify what type of severity |
| warnings are to be sent to the destination entered above. |
| • critical – Entering this parameter along with the proper |
| destination, stated above, will instruct the Switch to send only |
| critical events to the Switch’s log or SNMP agent. |
| • warning – Entering this parameter along with the proper |
| destination, stated above, will instruct the Switch to send |
| critical and warning events to the Switch’s log or SNMP agent. |
| • information – Entering this parameter along with the proper |
| destination, stated above, will instruct the switch to send |
| informational, warning and critical events to the Switch’s log or |
| SNMP agent. |
Restrictions | Only |
|
|
Example usage:
To configure the system severity:
73