3.Service menu

━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

(2)Cycle time : Number of the cycle played during the operation time. it is counted at the step 1. And through the robot is stopped during operation, counting is continued. (It is reset as exceeding 255 times)

(3)GUN ON Time : Gun signal output time per one cycle during operation.

(After the lamp is on, it is reset after 24 hours)

(4)GUN ON count: Gun On signal output per 1 cycle in the operation. ( After the lamp on, it is reset as exceeding 65535 times.)

3.7.2.2Total Run time

Outline

Total amount of the operation time after power on. Total cycle time, total GUN ON time, and total Gun On count are as above, too.

Screen display

14:39:38

***

Run time ***

A:0 S:4

 

 

 

 

 

 

*Total run time

=0:0: 0.00

 

 

Total cycle count =0

 

 

 

GUN1 time =0:0:

0.00

count=0

GUN2 time =0:0:

0.00

count=0

GUN3 time =0:0:

0.00

count=0

GUN4 time =0:0:

0.00

count=0

DI Sig waiting time =0:0: 0.00

Timer waiting time =0:0: 0.00

Press [ESC] or [R..]

>

3.7.2.3Operation time reset

Outline

(1)

Clear all data

..... All

data is cleared

(2)

Clear run

time

..... Total work time is cleared.

(3)

Clear

cycle count

..... Total cycle

time

is cleared

(4)

Clear

gun

data

..... Total

GUN ON

time

and count are cleared.

Operation method

The following is displayed as selecting 3: Clear all data, 4: Clear run time, 5: Clear

----------------------------------------------------------------------------------------

3 - 72

Page 141
Image 141