6. System setting

------------------------------------------------------------------------------------------------

Terminal name

Pin number

Signal

 

1

Channel 0

output

 

2

AGND (Analog ground)

 

3

Channel 1

output

TBA0

4

AGND (Analog ground)

5

Channel 2

output

 

 

6

AGND (Analog ground)

 

7

Channel 3

output

 

8

AGND (Analog ground)

Screen display

14:39:38 ** Speed by voltage ** A:0 S:4

 

Minimum voltage

= [

-3.7

]

(V)

 

Maximum voltage

= [

-0.2]

(V)

 

Minimum speed

= [3368.0]

(mm/sec)

 

Maximum speed

= [6524.0]

(mm/sec)

 

Port No.

= [ 160] 0=>No output

 

 

 

 

 

 

 

Select and Enter

number. Press [SET]

 

 

 

 

 

 

 

 

 

 

 

>[-12.0 - 12.0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference

(1)In case of selecting the " SERVICE"[PF1] → 1.Monitering → 19.Analog data, you can do the monitoring on the input/output state of analog input/output signal.

(2)The speed proportion output data is taken in custody in the control constant file. (ROBOT.C00)

(3)It can't be changed in case that the control constant file(ROBOT.C00) is completely protected.

----------------------------------------------------------------------------------------

6 - 97

Page 261
Image 261
Hyundai HI4 operation manual Pin number Signal, Output, 143938 ** Speed by voltage ** A0 S4, Port No