Hyundai HI4 Monitoring, 143938 ** DI Sig assignment ** A0 S4, External start External stop

Models: HI4

1 427
Download 427 pages 29.73 Kb
Page 185
Image 185

6. System setting

------------------------------------------------------------------------------------------------

14:39:38 ** DO Sig assignment **

A:0 S:4

 

 

 

 

 

 

 

 

GUN (squeeze) Sig = G1 [

1

]

 

G2 [

2]

MX(Unfolding) Sig = X1 [

3]

 

X2 [

0]

Alarm to welding system

 

 

=

[

0]

Weld stick warning

 

 

=

[

0]

Program end

 

 

=

[

7]

Synthetic error

 

 

=

[

8]

Emegency stop

 

 

=

[

0]

Manual mode

 

 

=

[

0]

Collision sense

 

 

=

[

0]

Step set warning

 

 

=

[

0]

Interlock-abnormal warning

=

[ 13]

 

 

 

 

 

 

 

Select and Enter number. Press

[SET]

 

 

 

 

 

 

 

 

 

>[1 - 256]

 

 

 

 

 

 

All Form

One Form

Previous

Next

 

Complete

One initialize: Presently selected output assignment signal value return to the initialize status.

Assigned DO signal displays the small character in the "Service"[PF1] → 1.

MONITORING.

 

 

ex) In

case of not assigning :

O31

In

case of assigning

:

o31

If press “ Complete” [PF5], Save changed information. if press [Cancel]Key, Cancel them.

6.2.1.7Input signal assignment

Outline

It uses the signal after output signal assign in special DI signal.

Screen display

14:39:38 ** DI Sig assignment ** A:0 S:4

External start

 

 

 

=

[

23

]

External stop

 

 

 

=

[ 24]

Prog selection bit=

BO1[ 25]

 

BO2[ 26]

 

 

 

 

BO3[ 27]

 

BO4[ 28]

 

 

 

 

B05[ 29]

 

BO6[ 30]

 

 

 

 

B07[ 31]

 

BO8[ 32]

Program Strobe

 

 

 

=

[

 

0]

Binary/Discrete(OFF->Binary) =

[

 

0]

External reset

 

 

 

=

[

 

0]

Low speed command

 

 

 

=

[

 

0]

WI

=

W1 [ 22]

 

W2 [

0]

 

 

 

 

 

 

 

 

Select and Enter number. Press

 

[SET]

 

 

 

 

 

 

 

 

 

 

 

 

 

>[1-256]

 

 

 

 

 

 

 

 

 

All Form

One Form

Previous

Next

 

Complete

----------------------------------------------------------------------------------------

6 - 21

Page 185
Image 185
Hyundai HI4 Monitoring, 143938 ** DI Sig assignment ** A0 S4, External start External stop, Program Strobe, External reset