3.Service menu

━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

3.7.3 Diagnosis of troubles

Outline

Displays the error diagnosis method of the robot.

When error occurs in the robot, it helps to main

Screen display

14:39:38 * Error code number * A:0 S:4

E0110 Discharge resister overheated.

Error code Number [ 110]

Phenomena

Check point: 1

If you short-circuit TS1 and TS2 on the Amp. any error occus?

(YES / NO)

Press

[PF1],[PF2],[PF3]

or [ESC]key!

 

 

 

 

 

 

 

 

 

 

 

 

>[1 -

1200]

 

 

 

 

 

Yes

 

No

Return

 

 

 

 

 

 

 

 

 

Operation method

In the diagnosis of the displayed error, select "YES"[PF1] key or "NO"[PF2]key for the question to the check point.

When you diagnosis the error with the exception of the displayed one, specify the error number and press [SET] key, and then "Execute" [PF5]key.

Or when your diagnose a trouble, select the item of the extraordinary using , key and press [SET] key, then following is displayed.

14:39:38 *** Phenomenon *** A:0 S:4

Phen1:Some axes do not move

Phen2:Malfunction of teaching pendant

Phen3:PLYBCK Pts mismatch recorded Pts

Phen4:Variation of playback point

Use [UP][Down]key and press [PF5]

>

Check!

Use the arrow , key to highlight the item about the state of the robot and press “ Check!” [PF5] key. Then answer to the displayed check point item by "Yes"[PF1] key

----------------------------------------------------------------------------------------