9.Quick Open Function

------------------------------------------------------------------------------------------------

9.10 SPOT WELDING FUNCTION

Outline

When SPOT or M72 (spot welding function) is recorded as a function in editing program,

if you press key after moving a cursor on, the screen is displayed as followings.

14:39:38*Servo-gun Welding Data*A:0 S:4

1:Welding condition

2:Welding sequence

Use [Number]/[Up][Down]and press [SET].

>

9.10.1 welding condition

If you select welding condition, following screen is displayed. The details about screen are referred to “ system” [PF2] → 4: application parameter → 1: spot & stud → 3: spot welding data (condition, sequence) → 2: welding condition part. The difference from this part is that the number of welding condition can not be changed but only the parameter about number of relevant welding condition can be changed.

14:39:38

*** Weld Condition *** A:0 S:4

 

 

 

 

 

 

 

 

 

 

Welding

Cond.

1

 

 

 

 

 

 

 

 

 

 

 

Output

data

=[

1

]

 

 

 

Output

type

=< Discrete,

Binary

>

Squeeze

force

=[ 50](Kgf)

Select and Enter number. Press [SET]

>[50 - 999]

----------------------------------------------------------------------------------------

9 - 18

Page 354
Image 354
Hyundai HI4 operation manual Spot Welding Function, 143938*Servo-gun Welding Data*A0 S4 Welding condition