6.System setting

------------------------------------------------------------------------------------------------

6.2.1.10.4Output signal assignment

Outline

It sets each signal group unit how you will map each output.

Screen display

14:39:38*** Assign Outpur No *** A:0 S:4

Assign Output No

to Fbus Data

 

0

O1

-

O8

->

[

0

]

Fbus_0

 

1

O11

-

O18

->

[ 1]

Fbus_1

 

2

O21

-

O28

->

[ 2]

Fbus_2

 

3

O31

-

O38

->

[ 3]

Fbus_3

 

4

O41

-

O48

->

[ 4]

Fbus_4

 

5

O51

-

O58

->

[ 5]

Fbus_5

 

6

O61

-

O68

->

[ 6]

Fbus_6

 

 

 

 

Page 1/4

 

 

 

 

 

 

 

 

 

 

 

Set

Fbus element No to map to output

 

 

 

 

 

 

 

 

 

 

>[0

- 31]

 

 

 

 

 

 

 

 

All

Form

 

Previous

 

Next

Done

„Please press [SET]key after inputting Fbus data that should use the output to be mapped in the standard output signal.

Reference

„The first data of Fbus data is redeployed if press "ALL Form"[PF1.].

„If you press “ Done” [PF5] key, Save the changed information. If press [CANCEL] key , Cancel them.

Caution

Do always in the off status in case of not building in BD470. If you put in the On status without building in BD470, All of the I/O function don't work with occurring the error in the controller.

----------------------------------------------------------------------------------------

6 - 30

Page 194
Image 194
Hyundai HI4 operation manual 143938*** Assign Outpur No *** A0 S4, Form Previous