Image 290

7.R code

------------------------------------------------------------------------------------------------

7.9 (9) R45 CONVEYOR REGISTER MANUAL INPUT

Outline

It sets Conveyor Register (CR) value as a manual inputted value.

If this function activated, the Conveyor Pulse (CP) value shall be automatically modified in connection with Conveyor Register (CR) value.

It is the same function with CR viewed at 1. Conveyor Simulation Date Access of "Service"[PF1] -> 2.Register setting -> 6. Conveyor Data

Screen display

Warning!)Change Conveyor Register? [Y/N]

>

Service

System

Rel.WAIT

 

Cond Set

 

 

 

 

„If you select [YES] , can input Conveyor Register value by manual, if you select [NO] , this function shall be cancelled.

 

 

 

 

 

 

Enter

CR value. (-99999.9 - 99999.9 mm)

 

 

 

 

 

 

>R45,

 

 

 

 

 

Service

System

Rel.WAIT

 

Cond Set

 

 

 

„To finish, press [SET] key following input number.

Reference

It cannot be executed during operation.

In case of the Limit switch is not activated, the CP/CR value shall not be increased, even if the manually inputted Conveyor Register(CR) value is not '0'.

----------------------------------------------------------------------------------------

7 - 14