6. System setting

------------------------------------------------------------------------------------------------

6.1.3 Start type

Outline

Define starting method of robot system. Same as pressing “ R5: external start selection (Enable/Disable) of R code

① Internal : Press start button in OP panel to start the robot

External : Start the robot by receiving external digital signal . Refer to chapter 12 Signal Connection → 1. External start of Standard Input signal.

Remote : Start the robot by receiving command from Central control unit. This is not supported in Hi4 controller

Reference

„Operator is in the range of robot working range or within safety fence, in case of setting external or remote start for start type, robot might automatically move certainly even though stop lamp in control cabinet is displayed because external or remote start signal can be activated at any time. For safety, start type of robot shall be set as internal start.

6.1.4 Change of cursor position in Auto mode

Outline

Decide cursor to be moved for step or function with Enable or Disable setting in Auto mode. For safety, manufacturer recommend disable setting.

Disable : Disable cursor movement for Step or Function in Auto mode

② Enable : Enable cursor movement for Step or Function in Auto mode

Reference

„As setting cursor position change <Disable>, the following message is displayed when up/down cursor key is pressed in Auto Mode.

Inhibit cursor step change on AUTO MODE

>

 

 

Service

Rel.WAIT

Cond Set

----------------------------------------------------------------------------------------

6 - 7

Page 171
Image 171
Hyundai HI4 operation manual Start type, Change of cursor position in Auto mode, Service Rel.WAIT