6. System setting

------------------------------------------------------------------------------------------------

6.4.6 Conveyor

Outline

It sets a variety of parameter to use the conveyor synchronous function and also a variety of condition to decide the motions shape of conveyor synchronous playback.

The conveyor synchronism should be set to the <ON> in "SYSTEM"[PF2] → 5. Initialization → 2.Robot type selection.

Please refer to the "User manual on the conveyor function" for the precise contents.

Screen display

14:39:38

*** Conveyor ***

A:0 S:4

1:Conveyor parameter setting

2:Conveyor angle/centr auto-set

Use [Number]/[Up][Down] and press [SET].

>

Previous Next

Reference

„The conveyor constant is taken in custody in the control constant file.(ROBOT. C00)

„It can't be changed in case that the control constant file(ROBOT.C00) is completely taken in custody.

----------------------------------------------------------------------------------------

6 - 91

Page 255