3. Service menu

------------------------------------------------------------------------------------------------

3.1.16Break Slip Count

Outline

You can select/ display the slip count value over the range and initialize it when you use in stud welding(Break ON type). You must select "System[PF2]" -> 5. System format -> 4: Setting usage of the robot, set the menu Stud in GUN1 or GUN2.

Screen display

14:39:38 * Slip count display * A:0 S:4

1:Slip count display/setting

2:Slip count reset

Use [Number]/[Up][Down] and press [SET].

>

3.1.16.1Slip Count display/setting

Outline

It displays the number of the break slip count in each axis and it is set the slip count by user. You must select " System[PF2] -> 5. System format -> 4: Setting usage of the robot, set the menu Stud in GUN1 or GUN2.

Screen display

14:39:38 * Slip count display * A:0 S:4

S: [

0

]

H :[

0]

V: [

0]

R2:[

0]

B: [

0]

R1:[

0]

Enter number and press [SET]

>[0 - 65535]

----------------------------------------------------------------------------------------

3 - 9

Page 78
Image 78
Hyundai HI4 operation manual Break Slip Count Outline, Slip count reset, Use Number/UpDown and press SET