3.Service menu

━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

3.2.1 XYZ Shift Register

Outline

It is keeping the tool angle of point that is already taught and a parallel movement in XYZ dimension. XYZ register reserves 3 dimension of shift data.

Screen display

14:39:38

 

 

*** Register ***

A:0 S:4

 

 

 

 

 

 

# XYZ shift

register

 

 

 

 

 

 

 

X=[

 

0.0

]

Y=[

0.0] Z=[

0.0]mm

 

 

 

 

 

 

 

Select and Enter number. Press [SET]

>[-3000.0 - 3000.0]

Complete

Operation method

After moving the cursor to changing the position, and press [SET] after inputting the numeric value with a numeric key.

If setting is ended, press 'Complete"[PF5] and the data is saved. If press 'Cancel" and it is canceled.

Reference

Playback of XYZ shift function

You must set the length in the direction of X,Y, and Z axis to the GUN -end exactly because translation is keeping the GUN angle.

Application of XYZ shift function

In case of translating the work parallel from the points A, B, C and D to the points a, b, c and d.

----------------------------------------------------------------------------------------

3 - 16

Page 85
Image 85
Hyundai HI4 operation manual XYZ Shift Register, Register A0 S4, Select and Enter number. Press SET, Complete