Image 239

6. System setting

------------------------------------------------------------------------------------------------

pressurization table can set the current value on the pressurization of 5 unit choosed freely.

Reference

Certainly, set a data before using the servo gun function.

In case that the set point is improper, even if the "PF5"[Completion] key is pushed, it isn't changed. Therefore, please set to proper value again as follows.

-The large open stroke should be set to being within the range of soft limit.

-The small open stroke should be set to being smaller value than that of

the large open stroke.

-The movable electrode clearance should be set to being smaller value than that of the small open stroke.

In the multi-gun, it is possible in motor-off to register the pedestal gun. but in case of being set together with the robot gun, it can't do motor-on. therefore you should select either all of the robot guns or all of the pedestal guns.

The number of pedestal gun coordinate system is effective only in case of that the gun type is a pedestal gun.

The pressurization force-electric current table should be set by measuring with the pressurization force gauge because it can be different according as whether the movable electrode is a gravity direction or half-gravity direction.

Please refer to the specification manual on servo gun function for the precise contents of parameter.

----------------------------------------------------------------------------------------

6 - 75