6. System setting

------------------------------------------------------------------------------------------------

6.4.1.3.3Welding sequence

Outline

It is a data that decides the welding sequence of controller in the playback of the spot welding.

Screen display

14:39:38 *** Weld Sequence *** A:0 S:4

Number

=[

1

]

 

 

 

 

 

Condition signal

=< DSBL,

ENBL

>

Squeeze signal

=<

DSBL

,ENBL >

Welding command signal

=< DSBL,

ENBL

 

>

WI wait

=< DSBL,

ENBL

>

Welding wait time

=[0.00]

 

 

 

 

Welding end wait time

=[0.00]

 

 

 

 

Select and Enter number. Press [SET]

>[1 - 64]

Contents of the screen

„Number : It is the number that designates in the spot welding function and there are 64 unit.

„Condition signal : It designates whether to output the welding condition signal or not. Currently, this item is fixed to <Enable>.

„Pressurization signal : It designates whether to output the pressurization signal or not. Currently, this item is fixed to <Disable>.

„Weld signal : It designates whether to output the weld signal or not. Currently, this item is fixed to <Enable>.

„WI wait : It designates whether to do the welding completion wait or not after outputting the weld signal. Currently, this item is fixed to <Enable>.

„Weld wait time : It designates the wait time of welding completion signal after outputting the weld signal. The 0.0 is the infinite wait.

„Welding completion wait time : It designates the wait time of until the gun opens after completing the welding. But in case that the gun open time is short, the

----------------------------------------------------------------------------------------

6 - 79