6. System setting

------------------------------------------------------------------------------------------------

„If press [SET]key after the standard [0] input the input source of the screen that is displayed in the present teach pendent change <STANDARD>.

„If press [SET]key after the field bus [1] input the input source of the screen that is displayed in the present teach pendent change <Fbus>.

The present setting item will save if press “ Done” [PF5], it will not save if press [CANCEL].

6.2.1.10.3Input signal assignment

Outline

It sets each signal group unit how you will map each input.

Screen display

14:39:38 *** Assign Input No *** A:0 S:4

Assign Input No to Fbus Data

 

 

 

 

 

 

 

0

DI1 -

DI8

<-

[

0

]

Fbus_0

1

DI9 -

DI16

<-

[ 1]

Fbus_1

2

DI17 -

DI24

<-

[ 2]

Fbus_2

3

DI25 -

DI32

<-

[ 3]

Fbus_3

4

DI33 -

DI40

<-

[ 4]

Fbus_4

5

DI41 -

DI48

<-

[ 5]

Fbus_5

6

DI49 -

DI56

<-

[ 6]

Fbus_6

Page 1/4

Set Fbus

element No to map

to input

 

 

 

 

 

 

>[0

- 31]

 

 

 

All

Form

 

Previous

Next

Done

„Please press the [SET] after inputting the Fbus data that should use the input to be mapped as the input signal.

Reference

„The first data of Fbus data is redeployed if press "ALL Form” [PF1].

„If you press “ Done” [PF5] key, Save the changed information. if press [CANCEL] key , Cancel

them.

----------------------------------------------------------------------------------------

6 - 29

Page 193
Image 193
Hyundai HI4 operation manual 143938 *** Assign Input No *** A0 S4, DI1, DI9, Previous Next Done