Hyundai HI4 operation manual Common Data A0 S4, Press SHIFT+-- Key

Models: HI4

1 427
Download 427 pages 29.73 Kb
Page 241
Image 241

6. System setting

------------------------------------------------------------------------------------------------

6.4.1.3.1Common data

Outline

It is a data which is applied in commonness without having concern with the welding condition or sequence number.

Screen display

14:39:38

*** Common

Data

*** A:0 S:4

 

 

 

 

 

 

 

Error processing

=<

Interlock,

Stop

>

GUN open to error

stop =<

DSBL,

ENBL

>

 

WI common use

 

=<

DSBL

,ENBL

>

 

Press [SHIFT]+[<-][->] Key.

>

Contents of the screen

„Treatment in the error : It is a treatment when the welding completion signal isn't inputted.

Interlock wait : It wait until the welding completion signal is inputted.

Stop : If the welding completion signal isn't inputted, it makes the robot stopped by treating as an error.

„Gun open in the error/stop : It opens the servo gun and stops when the error or stop occurs under the welding.

„WI common use : It is a data that decides whether the welding completion signal uses in commonness or not in case of using the servo gun more than two.

Disable : It doesn't use the welding completion signal in commonness.

Enable : It use the welding completion signal in commonness.

----------------------------------------------------------------------------------------

6 - 77

Page 241
Image 241
Hyundai HI4 operation manual Common Data A0 S4, Press SHIFT+-- Key