9. Quick Open Function

------------------------------------------------------------------------------------------------

9.6 WELDING AUXILIARY CONDITION - RESTART

Outline

If you select “ aux. condition” [PF1] at the welding start condition screen and press “ restart” [PF1], restart setting screen is displayed as followings

Entry screen

14:39:38** Arc Condition File **A:0 S:4

ARC AUXILIARY CONDITION FILE

<RESTART>

 

 

 

Repetition

: [2] Times

 

 

Overlap Length

: [

5.0

] mm

Speed

: [ 27]

cm/min

Current

: [

0]

A

Voltage

: [

0.0] V

 

OVERLAP CONDITIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Arc Off

: <

Stop

,Conti,SemiAuto,Auto>

 

 

Gas Off

: <

Stop

,SemiAuto>

 

 

 

 

Wire Off : <

Stop

,SemiAuto>

 

 

 

 

 

 

 

 

 

 

 

Select and Enter number. Press [SET]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

>

 

 

 

 

 

 

 

 

 

 

 

 

Retry

 

ASF

 

 

Save

 

Screen contents

„Number of times : It assigns max. repeating number of times of restart process in the same welding area.

„Amount of superposition : It is the distance of superposition(Overlap distance) when a restart. It starts to weld after returning as long as a superposition distance.

„Speed : It is a speed of overlapping after moving to superposition position. When error occurs, it has three times of assigned speed when it moves as long as overlap distance, and this speed is applied when it welds in overlap area. After welding in Overlap section, the normal welding speed is applied.

 

 

 

 

 

Overlap

 

 

distance

Speed in restart process

----------------------------------------------------------------------------------------

9 - 11

Page 347
Image 347
Hyundai HI4 operation manual Welding Auxiliary Condition Restart, ARC Auxiliary Condition File Restart, Retry