3.Service menu

━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

3.2.3 On-line shift register Group

Outline

On-line shift register group is a register that is set each axis length the palletize turning number, shift data to be received from the external unit. There are total 8 units. It can be set double register.

Screen display

14:39:38

*** Register ***

A:0 S:4

1:ON-line shift register 1

2:ON-line shift register 2

3:ON-line shift register 3

4:ON-line shift register 4

5:ON-line shift register 5

6:ON-line shift register 6

7:ON-line shift register 7

8:ON-line shift register 8

Use [Number]/[Up][Down] and press [SET].

>

Operation method

Select register group to set. If register group 1 selected, it displays as follow;

14:39:38

*** Register ***

A:0 S:4

#On-line shift register group [Register1]

Request port No.=[] Input state=[0]

X=[

0.0]

Y=[

0.0]

Z=[

0.0]mm

AX=[

0.00]

AY=[

0.00]

AZ=[

0.00]dg

Select and Enter number. Press [SET]

>[0 - 2]

Complete

Screen description

Request port No. : Input the number of serial port to be inputted from vision equipment

Input value : If the shift value from vision equipment inputted and changed position data, it changes to "1".

----------------------------------------------------------------------------------------

3 - 20

Page 89
Image 89
Hyundai HI4 operation manual On-line shift register Group, Register A0 S4 ON-line shift register