6.System setting

------------------------------------------------------------------------------------------------

6.2.1.6Output signal Assignment

Outline

It uses the signal after output signal assign in special DO signal.

Screen display

14:39:38 ** DO Sig assignment **

A:0 S:4

 

 

 

 

 

 

 

 

GUN (squeeze) Sig = G1 [

23

]

 

G2 [ 24]

MX(Unfolding) Sig = X1 [ 25]

 

X2 [

0]

Alarm to welding system

=

[

0]

Weld stick warning

=

[

0]

Program end

=

[ 26]

Synthetic error

=

[ 27]

Emegency stop

=

[

0]

Manual mode

=

[

0]

Collision sense

=

[

0]

Step set warning

=

[

0]

Interlock-abnormal warning

=

[ 28]

 

 

 

 

 

 

 

Select and Enter number. Press

[SET]

 

 

 

 

 

 

 

 

 

 

>[1 - 256]

 

 

 

 

 

 

 

All Form

One Form

Previous

Next

 

Complete

Reference

All Initialize: It initializes all of assigned output signal. It displays the following massage on the screen if you select All initialize function.

All Init.?Hardwiring:0,Fieldbus:1(0 - 1)

>[0 - 1]

All FormOne FormPrevious Next Complete

„If you select the standard number "0", All of assigned signal changes the initializing value.

„If you select the field bus(1), It redeploys output assignment signal to use the field bus. if you select the field bus(1), it displays the following massage.

Input the start port number.(1 - 32)

>[1 - 32]

All FormOne FormPrevious Next Complete

Input the start port number to be assigned. if the start port number select "1", it displays the following massage.

----------------------------------------------------------------------------------------