5.Application condition

------------------------------------------------------------------------------------------------

5.2 Search Range

Outline

Define the range to be searched when you use search function.

X value can be set between 0.03.0 and the range is as follows.

Teaching Point

Teaching Point

 

L

 

----------------------

--------------

Search

Range = L(1+X)

 

 

 

 

5.3 Search reference position record

Outline

Search reference data is automatically recorded with reference position value of workpiece after 1 cycle playback, as setting search function ON upon the condition that workpiece is placed after the completion of teaching including search function.

Off : Disable search reference position data record function.

② On : Enable search reference position data record function.

Reference

„The following is displayed in manual or auto mode as setting search reference position data record "On"

14:39:38

*** A U T O ***

A:0 S:4

T0 SW

 

SR:100% 1Cycl

PN:100[*]__ S/F:4/0

 

 

Robot:H120, 6axes, 10 steps

S1

MOVE P,S=100%,A=0,T=1

 

S2

MOVE P,S=100%,A=0,T=1

 

S3

MOVE P S=100% A=0 T=1

 

>

 

 

 

Service

Rel WAIT

Cond Set

State of search reference position record.

„1 cycle playback shall have the same speed of normal playback at recording search reference position data.

----------------------------------------------------------------------------------------

5 - 4

Page 161
Image 161
Hyundai HI4 operation manual Search Range, Search reference position record, Move P S=100% A=0 T=1, Service Rel Wait