9.Quick Open Function

------------------------------------------------------------------------------------------------

forward after retracting in certain amount of distance, the voltage/current condition follows the welding start condition.

Shift : After moving in scheduled moving amount at the retry condition of welding aux. condition, it returns to the arc occurrence step. And it tries to make an arc occurrence in the voltage/current condition at retry condition.

③ welding line move: After moving by scheduled distance at the retract distance of welding aux. condition's retry condition with welding line, it tries to make an arc occurrence in the scheduled voltage/current condition at retry condition. If the arc occurrence is success, after it returns to the welding start point again with holding this arc, it processes the welding.

„Output current : It inputs the welding current value to output at welding power machine.

„Output voltage : It inputs the welding voltage value to output at welding power machine.

„WCR input wait : It selects whether waiting WCR input or not waiting and just processing after outputting the welding condition.

„Wait time : In case that WCR input wait is “ enable” : it displays “ wait time” . timeout time, that is WCR input maximum wait time, it processes even though the signal is not detecting.

In case that WCR input wait is “ disable” : it displays “ delay time” . It is the time when robot is not moving after outputting the condition.

„Gas blowing out : It inputs the time of gas to blow out before the arc welding starts.

„Initial condition time : After WCR is input, it sets the holding time of initial current and voltage.

„Initial current : It sets the current value until WCR is input.

„Initial voltage : It sets the voltage value until WCR is input.

„Output type : While an arc welding, it selects whether you make it steep or unchangible which is the status of current and voltage from initial time to the steady state.

Reference

(1) [cancel] ends without saving, “ completion” [PF5] ends after saving the changed items.

----------------------------------------------------------------------------------------