Hyundai HI4 operation manual Arcof Command, Arccur Command, Arcvol Command

Models: HI4

1 427
Download 427 pages 29.73 Kb
Page 387
Image 387

11.Robot Language Explanation

------------------------------------------------------------------------------------------------

11.2.6.2ARCOF Command

 

Description

 

Outputs the Welding End Command.

 

 

 

 

 

 

 

 

 

 

 

 

ARCOF

 

 

 

 

 

Syntax

 

ARCOF AEF#=<File Number>

 

 

 

ARCOF C=<Current Output Value>, {V=<Voltage Output Value> VP=<Voltage Rate>}

 

 

 

 

 

 

[,T=<Time>] [,ANTSTK]

 

 

 

 

 

File

Arithmetic Equation. Number of welding end condition

Rounded. 132

 

 

 

Number

file.

 

 

 

 

 

Current

Arithmetic Equation. Welding current output

Unit: A Rounded

 

 

 

Output

value(0500)

 

 

 

 

Value

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Arithmetic Equation. Welding voltage output value

Unit: V [0.0]

 

 

 

Output

(Separate power source) (040)

 

Parameter

 

Value

 

 

 

 

 

 

 

 

 

 

Voltage

Arithmetic Equation. Voltage output rate about the

Unit: % Rounded

 

 

 

Rate

appropriate welding voltage (Single power source)

 

 

 

(0100)

 

 

 

 

 

 

 

 

 

 

 

Time

Arithmetic Equation. The delay time of the robot body

Unit: sec

 

 

 

before the ARC Off. (010)

[0.00]

 

 

 

 

 

 

 

ANTSTK

Automatic Anti-Stick feature

 

 

 

 

 

 

 

 

 

 

example

 

ARCOF AEF#=1

 

 

 

 

ARCOF C=300, V=V10!, T=1.00, ANTSTK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The result for each usage is as follows;

 

 

 

 

1. ARCOF

: Welding ends as previously set by the condition with ARCCUR, ARCVOL

 

Comment

 

commands.

 

 

 

 

 

2. ARCOF <File> : Welding ends as set by the conditions of the condition file.

 

 

 

3. ARCOF <Parameters> : Welding ends as set by the conditions of the parameters.

 

 

 

 

 

 

 

11.2.6.3 ARCCUR Command

 

 

 

 

 

 

 

 

 

 

Description

 

Sets the welding current output value with the set value.

 

 

 

 

 

 

 

 

 

Syntax

 

ARCCUR C=<Current Output Value>

 

 

 

 

 

 

 

 

 

 

Parameter

 

Current Output Value

Arithmetic Equation. Welding current

Unit: A

 

 

output value (0500)

Rounded.

 

 

 

 

 

 

 

example

 

ARCCUR C=200

 

 

 

 

 

 

 

 

 

11.2.6.4 ARCVOL Command

 

 

 

 

 

 

 

 

 

Description

 

Sets the welding voltage output value with the set value

 

 

 

 

 

 

 

 

Syntax

 

ARCVOL {V=<Voltage Output Value> VP=<Voltage Rate>}

 

 

 

 

 

 

 

 

 

 

Voltage Output

Arithmetic Equation. Welding voltage output

Unit: V [0.0]

 

 

 

Value

 

value (040)

 

 

Parameter

 

Voltage Rate

Arithmetic Equation. The voltage rate about

Unit: %

 

 

 

the appropriate welding voltage (Single power

Rounded.

 

 

 

 

 

source) (0100)

 

 

example

 

ARCVOL V=30

 

 

 

 

 

 

 

 

 

 

----------------------------------------------------------------------------------------

11 - 22

Page 387
Image 387
Hyundai HI4 operation manual Arcof Command, Arccur Command, Arcvol Command