6.4.2 Arc

Outline

It sets a function to do the arc welding.

Please refer to the "Operation manual on the HR controller" for the precise contents.

Screen display

14:39:38

*** Arc Weld ***

A:0 S:4

 

 

 

 

 

1: Condition Parameter

 

 

Use [Number]/[Up][Down] and press [SET].

>

Previous Next

Reference

„The arc condition parameter is taken in custody in the control constant file (ROBOT.C00).

„It can be changed in case that the control constant file (ROBOT.C00) is completely taken in custody.

6.4.2.1Condition parameter

Outline

It sets a variety of condition for the welding work in the arc welding.

Screen display

14:39:38

** Arc Weld **

A:0 S:4

1:Fast step Go/Back = Max.speed*[ 1]%

2:Inching Spd: Slow=[ 1]%,Fast=[ 1]%

3:Assign Welding Current Port =[ 0]

4:Assign Welding Voltage Port =[ 0]

5:Assign [ARC On] state output =[ 0]

6: Welder error input

=<

DSBL

,ENBL>

7: Welding wire state

=<

DSBL

,ENBL>

8: Shield Gas state

=<

DSBL

,ENBL>

 

 

 

 

9:Feeder Ty=(Motor & Dir.)=<DSBL,ENBL>

10:Gas Postflow at weld stop =[ 0.0]sec

Enter number and press [SET]