7. R code

------------------------------------------------------------------------------------------------

7.8 (8) R44 CONVEYOR DATA CLEAR

Outline

It clears Conveyor data ; CP, CR, CS.

The content which will be cleared can be different according to the selected mode at "Cond Set"[PF5] -> "Applicnd"[PF1] -> 1: Conveyor oper = <Normal, Simulat, Test> as table.

 

General

Simulation

Test

 

 

 

 

CP(Pulse)

CLEAR

Keep present

CLEAR

pulse

 

 

 

 

 

 

 

CR(Distance)

CLEAR

CLEAR

CLEAR

 

 

 

 

CS(Speed)

CLEAR

CLEAR

Always '0'

 

 

 

 

It is the same function with 2.Conveyor data reset of "Service"[PF1] -> 2.Register ->

6.Conveyor Data.

Screen display

Conveyor data clear. Continue? [YES/NO]

>

Service

System

Rel.WAIT

 

Cond Set

 

 

 

 

„If you select [YES], the conveyor data shall be cleared. Otherwise, If you select [NO], this function shall be cancelled.

Reference

It cannot be executed during operation.

The limit switch input state will be cleared, too. So, to start pulse counting, it needs new limit switch input.

----------------------------------------------------------------------------------------

7 - 13

Page 289
Image 289
Hyundai HI4 operation manual 8 R44 Conveyor Data Clear