9. Quick Open Function

------------------------------------------------------------------------------------------------

9.3 WELDING START CONDITION - EXE. AT ASF#=x

Outline

If you press key, when a cursor is at the ARCON ASF#= instruction line, the edit screen appears as followings.

Entry screen

14:39:38** Arc Condition File **A:0 S:4

ARC START

CONDITION FILE

1/2

 

 

 

 

 

 

Cond No

: [

1

] (chg:[Sft]+[Up/Down])

Comment

: [Arc Start

Cond 1

]

 

 

 

 

 

 

 

Vol Confirm: <

Done

, Not

Done>

 

 

 

 

 

 

 

 

 

 

 

Retry

: <

OK

,No>

 

 

 

 

 

 

 

 

 

 

 

Retry Mode

: <Reenter,Shift,

Weld Path

>

Current

:

[200] A

 

 

 

 

Voltage

:

[ 20.0] V

 

 

 

 

 

 

 

 

 

WCR Wait

:

<Disable,

Enbale

>

 

 

Wait Time

:

[0.10] sec

 

 

 

 

Gas Preflow:

[ 0.5] sec

(if GasControl)

----------------------------------------

<Initial Condition (Disable:0sec)> 2/2

 

Initial Time

: [0.00]

 

sec

 

 

 

 

Initial Current

: [

0] A

 

 

 

 

 

 

 

Initial Voltage

: [

0.0] V

 

 

 

 

 

 

 

 

 

 

 

 

 

Output method

: <

constant

,Slope>

 

 

 

 

 

 

 

 

 

 

 

Select and Enter number. Press [SET]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

>

 

 

 

 

 

 

 

 

 

 

 

Aux Cond

Welder

Previous

 

Next

 

Save

 

screen contents

„con. No. : It assigns the welding con. No. (32 conditions are available.)

„explanation : It records the explanation about usage of the welding condition.

„voltage check : It sets whether the checked control method of welding power machine is unification or individuation.

„retry : In case of not detecting WCR signal after outputting ARCON signal, it determines whether using retry function or not.

„action mode : It is the moving direction of torch when it retries.

re-entry : In case that arc occurrence is failed, after moving back to before step, it tries to make an arc occurrence again. The moving distance can be set as retract distance on the welding auxiliary condition retry screen. Because it steps moving

----------------------------------------------------------------------------------------

9 - 5

Page 341
Image 341