Filtering/QoS Information

 

 

Parameter

 

<InterfaceDescription:name>

Specifies the subject interface name set in the ip information

 

or ip-address information. (The ip information or the ip-address

 

information should be set before inputting this command.) RM

 

Ethenet and Tunnel interface are not supported. For details,

 

refer to Table 1-5.

Default:

No default is possible.

{inDescription:out}

Specifies the Inbound/Outbound. Either one or both of the

 

Inbound/Outbound can be set against one interface.

in:

Inbound (specification of the frame input side)

out:

Outbound (specification of the frame output side)

Default:

No default is possible.

[-disable]Description:

Nullifies the flow control by input/output interface.

Default:

Flow control is executed.

listDescription:<ListNo.>

Specifies the list number.

Default:

Default is possible only in the indicated case. All the lists are

 

displayed at default.

Range of value:

1 to 20,000 (ten-decimals)

[listDescription:<ListNo.>-listSpecifies<listNothe.>]range of a list number. This parameter can be specified only when a blank list number is displayed.

Default:

The range of the list number being the object of indication will

 

the number of all the lists totaling the IPv4QoS list and

 

IPv6QoS list.

Range of value:

1-255 (decimal) are designated to <No>. (Ver. 05-01, Ver.

 

06-00)

 

1-1000000 (decimal) are designated to <No.>. (Ver. 06-01)

Description:

Displays the blank list number.

freeDefault:

Cannot be omitted when the blank list number is displayed.

Description:

Displays the top blank list number in the specified range.

min_Default:no

Cannot be omitted when the top list number of a blank list

number is displayed.

GR2K-GA-0014

1-65

Ver. 07-02

 

Page 107
Image 107
Hitachi GR2000 Series manual Parameter