Configuration Error Messages

 

 

Table 5-25 Other Error Messages (continued)

 

 

CAUTION: Current configuration file was

Current configuration file was copied, but because it cannot be

successfully changed. Configuration file do

copied to standby configuration file, standby configuration

not modified to standby RM because

information is not reflected. When updating standby configuration

configuration file copy failed.

file, reflect by using config copy command after eliminating causes of

 

error.

 

1. Confirm the MC card’s mounting status and the remaining

 

capacity in the standby system using the show mc command (*1).

 

2. Confirm the RM’s CPU use rate using the show “rm cpu”

 

command (*2).

 

3. Confirm that the standby system RM board has been inserted

 

into this device correctly.

CAUTION: Current configuration file was

Current configuration file was saved, but because standby RM is not

successfully saved. Update configuration file

ready, standby configuration information is not reflected.

do not copy to standby RM because standby

When updating standby configuration information, start up the

RM is not ready.

standby, and then reflect by using config copy command.

CAUTION: Current configuration file was

Current configuration file was saved, but because it cannot be copied

successfully saved. Update configuration file

to standby configuration file, standby configuration information is not

do not modified to standby RM because

reflected. When updating standby configuration file, reflect by using

configuration file copy failed.

config copy command after eliminating causes of error.

 

1. Confirm the MC card’s mounting status and the remaining

 

capacity in the standby system using the show mc command (*1).

 

2. Confirm the RM’s CPU use rate using the show “rm cpu”

 

command (*2).

 

3. Confirm that the standby system RM board has been inserted

 

into this device correctly.

CAUTION: Current configuration file was

Current configuration file was saved, but because standby

successfully saved. Update configuration file

configuration information is opened, standby configuration

do not modified to standby RM because

information is not reflected. When updating configuration information,

configuration file is opened in standby RM.

close standby configuration, and then reflect by using config copy

 

command.

CAUTION: Current configuration file was

Current configuration information file was copied, but because

successfully saved. Update Configuration file

standby configuration file cannot be modified, standby configuration

do not modified to stand by RM because

information is not reflected.

stand by RM is not ready.

When updating standby configuration file, reflect by using config

 

copy command after eliminating causes of error.

 

1. Confirm the MC card’s mounting status and the remaining

 

capacity in the standby system using the show mc command (*1).

 

2. Confirm the RM’s CPU use rate using the show “rm cpu”

 

command (*2).

 

3. Confirm that the standby system RM board has been inserted

 

into this device correctly.

CAUTION: Current configuration file was

Current configuration file was saved, but because standby

successfully saved.Update configuration file

configuration information cannot be copied to cached configuration

do not modified to standby RM because

file, standby configuration information is not reflected. When

cached configuration file create failed.

updating configuration information, confirm the rest memory size of

 

MC card by using show mc command, and then reflect by using

 

config copy command after eliminating causes of error.

CAUTION: Current configuration file was

Current configuration file was copied, but because standby

successfully changed. Configuration file was

configuration information is opened, standby configuration

not modified to standby RM because

information is not reflected. When updating standby configuration

configuration file is opened in standby RM.

file, close standby configuration, and then reflect by using config

 

copy command.

Command incomplete because processing

Because processing deletion of configuration is taking too much

configuration deletion exceeded time limit.

time, command is interrupted. Execute same command again.

To complete deletion, please try same

 

command again.

 

Configuration file can not open.

Configuration file cannot open. Confirm setting status and the rest

 

memory size of MC card by using show mc command.

 

 

 

 