Filtering/QoS Information

Displaying the first free entry No.

TCP,showUDP,qosand-ipother-listupperfreeminlevelnoprotocols specify the configurable parameters for flow detection, whereas the flow control parameters that can be configured depend on the type of flow-control process used. The following tables illustrate the configurable parameters for flow detection that are supported by various upper-level protocols, and the flow-control parameters that are supported by different flow-control methods. IP QoS settings are generated by selecting one parameter type from the flow-detection parameter table (see Table 1-82) and one from the flow-control type parameter table (see Table 1-83 to create one entry.

Table 1-82 Configurable Parameters for Flow Detection by Upper-level Protocol

Flow-Detection Parameter

Upper-Level Protocol

 

 

 

 

 

 

 

 

 

 

 

TCP

 

UDP

 

ICMP

IGMP

Unspecified

Other

 

 

 

 

 

 

 

 

 

 

 

 

<IP List No.>

††

††

††

††

††

††

 

 

 

 

 

 

 

 

 

-protocol <No.>

6

17

 

1

2

 

 

 

 

 

 

 

 

 

 

{-payload_length_upper_limit

 

 

-payload_length_lower_limit}

 

 

 

 

 

 

 

 

<Payload Length>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-tos <Value>

 

 

 

 

 

 

 

 

 

 

{-ip_pair -ip_pair_off}

*

*

 

*

*

*

*

 

 

 

 

 

 

 

 

 

-ip_source <IP Address> -<IP Address> mask

 

 

<Subnet Mask> masklen <Subnet Mask Bit Length>

 

 

 

 

 

 

 

 

/<Subnet Mask Bit Lendth>]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-ip_destination <IP Address> -<IP Address> mask

 

 

<Subnet Mask> masklen <Subnet Mask Bit Length>

 

 

 

 

 

 

 

 

/<Subnet Mask Bit Lendth>]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

{-port_pair -port_pair_off}

*

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-port_source <Port No.> [-<Port No.>]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-port_destination <Port No.> [-<Port No.>]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

{-pair_synchronized_off -pair_synchronized}

*

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-icmp_type <No.>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-icmp_code <No.>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-igmp_type <No.>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

††: required, †: configurable, *: configurable; default, blank: not configurable, numeral: numeric setting

GR2K-GA-0014

1-169

Ver. 07-02

 

Page 211
Image 211
Hitachi GR2000 Series manual Displaying the first free entry No, GR2K-GA-0014 169 Ver, Unspecified Other