Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2

Table 5-8 Flow Information Error Messages (continued)

Can not set upc because max_rate or

The band setting cannot be set because the maximum band

min_rate is already defined.

restriction or the minimum band assurance has been defined. To set

 

the band setting, delete the maximum band restriction or the

 

minimum band assurance.

Can not set upc because

It is not possible to set the bandwidth setting because the VLAN

replace_user_priority is already defined.

priority rewrite value is defined. Delete the VLAN priority rewrite

 

value in order to set the bandwidth setting.

Can not set upc_burst because upc not

The burst size cannot be set because the band setting has not been

specified.

defined. To set Upc_burst, set the band setting.

Can not set user_priority.

It is not possible to specify "replace_user_priority" except in

 

interfaces set by OutBound or VLAN.

class out of range

The input value is outside the specified range. Set the traffic class in

 

the range of 0 to 255.

discard out of range

The input value is outside the specified range. Set the queuing

 

priority in the range of 1 to 4.

Duplicate flow interface configuration.

Interface names are duplicated. Specify an interface using

 

"<Interface_Name> + in" as one, and interfaces duplicated either in

 

Filter or Qos cannot be specified.

Duplicate flow list No configuration.

List numbers are duplicated in the interface. Specify for the list

 

number the numbers not having been set.

entry_no in not in range of 1 to 20000.

The input value is outside the specified range. Set the list number in

 

the range of 1 to 20000.

exp out of range

The input value is outside the specified range. Set the exp field value

 

in the range of 0 to 7.

Filter configuration is already defined.

The flow filter cannot be set because filter has already been set.

 

To set the flow filter, it is necessary to delete the setting of filter_in.

Flow list IP_Address high is less then list

The IP address (high) is smaller in value than the IP address (low).

IP_Address.

Perform the setting so that the IP address (high) is greater in value

 

than the IP address (low).

Flow list Port_No high is less then list Port_No

The port number (high) is smaller in value than the port number

low.

(low). Perform the setting so that the port number (high) is greater in

 

value than the port number (low).

icmp_code out of range

The input value is outside the specified range. Set the ICMP code in

 

the range of 0 to 255.

icmp_type out of range

The input value is outside the specified range. Set the ICMP type in

 

the range of 0 to 255.

icmp6_code out of range

The input value is outside the specified range. Set the ICMP6 code in

 

the range of 0 to 255.

icmp6_type out of range

The input value is outside the specified range. Set the ICMP6 code in

 

the range of 0 to 255.

In case of inbound can not set

It is not possible to specify "replace_user_priority" in InBound of flow

replace_user_priority.

qos. Specify "replace_user_priority" in OutBound.

In case of inbound can not set vlan at VLAN

It is not possible to specify "vlan" in InBound of flow filter. Specify

interface.

"vlan" in OutBound.

In case of outbound can not set policy routing.

Policy, Policy_Group, and Policy_MPLS cannot be specified in

 

OutBound of the flow filter. Specify the Policy, Policy_Group, and

 

Policy_MPLS in the InBound

In case of outbound can not set user_priority.

It is not possible to specify "user_priority" in OutBound of flow qos.

 

Specify "user_priority" in InBound.

index out of range

The input value is outside the specified range. Set the connection

 

branching index number in the range of 0 to 7.

invalid IP_Address

The ip address value is invalid.

invalid IPv6_Address

The IPv6 address value is invalid.

list no. in not in range of 1 to 20000, 40001 to

The input value is outside the specified range. Set the list number in

60000.

the range of 1 to 20000 or 40001 to 60000.

 

 

5-70

GR2K-GA-0014

 

Ver. 07-02

Page 460
Image 460
Hitachi GR2000 Series manual Band setting, delete the maximum band restriction or