Hitachi GR2000 Series manual Filter function on the first input side stage

Models: GR2000 Series

1 500
Download 500 pages 15.25 Kb
Page 45
Image 45

 

Filtering/QoS Information

 

Filter function on the first input side stage

The first input side stage executes the following functions:

Filtering:

Relays or discards the packet in accordance with the flow

 

detecting condition.

DSCP rewriting:

Rewrites the DSCP field in accordance with the flow detecting

 

condition.

Policy routing:

Transmits the packet to the specified output destination in

 

accordance with the flow detecting condition.

 

￿

Constituting definition command

1, 2 flow filters (filter flow information)

 

QoS function on the second input side stage (flow control part)

 

The second input side stage executes the following functions:

 

Priority determination:

 

 

 

 

Determines the priority of the packet that agrees with the flow

 

 

detecting condition.

 

DSCP rewriting:

Rewrites the DSCP field of the packet that agrees with the flow

 

 

detecting condition.

 

 

Contract band monitoring:

 

 

 

 

 

Monitors if the packet that agrees with the flow detecting

 

 

 

condition is following or violating the contract band.

 

 

Constituting definition command

1, 3 flow filters (QoS flow information)

 

 

Filter function on the first output side stage

 

 

The first input side stage executes the following functions:

 

￿

Filtering:

Relays or discards￿

the packet in accordance with the flow

 

 

detecting condition.

 

DSCP rewriting:

Rewrites the DSCP field in accordance with the flow detecting

 

 

 

condition.

 

 

 

 

Connection branching:

 

 

 

 

 

Selects and transmits the packet to the specified DLCI/VC in

 

 

 

accordance with the flow detecting condition.

 

 

Constituting definition command

1, 2 flow filters (filter flow information)

 

 

Filter function on the second output side stage (flow control part)

 

 

The second output side stage executes the following functions:

 

 

Priority determination:

 

 

 

￿

 

Determines the￿priority of the packet that agrees with the flow

 

 

detecting condition.

 

DSCP rewriting:

Rewrites the DSCP field of the packet that agrees with the flow

 

 

 

detecting condition.

 

 

Contract band monitoring:

 

 

 

 

 

Monitors if the packet that agrees with the flow detecting

 

 

 

condition is following or violating the contract band.

 

 

EXP rewriting:

Rewrites the EXP field of the packet that agrees with the flow

 

 

 

detecting condition.

 

 

 

 

 

GR2K-GA-0014

 

 

￿

1-3

Ver. 07-02

￿

 

 

 

Page 45
Image 45
Hitachi GR2000 Series manual Filter function on the first input side stage, Packet in accordance with the flow