Configuration Error Messages

 

 

Table 5-8 Flow Information Error Messages (continued)

 

 

lower out of range

The input value is outside the specified range. Set the lower limit of

 

IP user data length in the range of 0 to 65535.

Masklen is not in range of 0 to 32.

The input value is outside the specified range. Set the mask length in

 

the range of 0 to 32.

max_rate is not in range of 0 to 2400000.

The input value is outside the specified range. Set the maximum

 

band restriction in the range of 0 to 2400000.

max_rate_burst is not in range of 0 to 131072.

The input value is out of the prescribed range. Set the range of 0 to

 

131072 to the maximum band limitation burst size.

Maximum number of Flow IPv6

The number of entries in an interface, including a flow IPv6 filter list,

Filter_interface configurations are already

which can be set per router exceeds the range. Set the interface,

defined.

including a flow IPv6 filter list, to within 128 entries per router.

Maximum number of Flow IPv6 Filter_list

The number of entries in a flow IPv6 filter that can be set per

configurations are already defined in one Flow

interface exceeds the range. Set the flow IPv6 filter to within 16

Filter_inteface configuration.

entries per interface.

Maximum number of Flow IPv6 Filter_list

The number of entry for the flow IPv6 filter that can be set per device

configurations are already defined.

has exceeded the range.

Maximum number of Qos/Filter IP Flow

The number of entries in a flow QoS/Filter that can be set per

configurations are already defined.

interface or router, exceeds the range. Set the flow QoS/Filter to

 

within 2000 entries per RP or 10000 entries per router.

min_rate is not in range of 0 to 2400000.

The input value is out of the prescribed range. Set the range of 0 to

 

2400000 to the minimum band guarantee.

min_rate or max_rate not specified.

The detection conditions of an important packet flow are set, but the

 

maximum band limitation or minimum band guarantee is not set. Set

 

the maximum band limitation or minimum band guarantee.

min_rate_burst is not in range of 0 to 131072.

The input value is out of the prescribed range. Set the range of 0 to

 

131072 to the minimum band guarantee burst size.

No enough parameters.

Parameters are insufficient. Specify the necessary parameters.

no such flow

Applicable flow configuration definition does not exist.

No such flow filter list No.

The specified list number does not exist because the action of a flow

 

filter was changed. Specify the previously set list number when

 

action was changed.

No such flow qos list No.

The specified list number does not exist because the action of a flow

 

qos was changed. Specify the previously set list number when action

 

was changed.

penalty_discard out of range

The input value is out of the prescribed range. Set the range of 1 to 4

 

to delete contract band breaching queuing priority.

penalty_tos out of range

The input value is out of the prescribed range. Set the range of 0 to

 

255 to delete contract band breaching tos rewrite value.

Policy interface name can not set at

The interface for the policy routing cannot be set in the interface of

rmEthernet.

mEthernet. Set other interface name.

Policy interface name not found at

The interface specified in the policy routing cannot be found. Set the

[<Interface_Name>]

interface name.

Policy_group name not found at

The specified in the policy group cannot be found. Set either the

[<Policy_Group_Name>].

policy routing or the policy group set in the policy routing.

port_destination out of range

The input value is out of the prescribed range. Set the range of 1 to

 

65535 to the destination port number.

port_source out of range

The input value is out of the prescribed range. Set the range of 1 to

 

65535 to the source port number.

precedence out of range

The input value is out of the prescribed range. Set the range of 0 to 7

 

to the precedence value.

prefixlen out of range

The input value is out of the prescribed range. Set the range of 0 to

 

128 to the prefix length.

priority out of range

The input value is out of the prescribed range. Set the range of 1 to

 

1000 to the output priority.

 

 

 

 

GR2K-GA-0014

5-71

Ver. 07-02

 

Page 461
Image 461
Hitachi GR2000 Series manual To the maximum band limitation burst size