If 0 to 4 is specified, the operation is performed by taking the contract band as 4.1[kbit/s].
<Byte>: 0 to 131072 (10-decimals)
If a value greater than the line speed is set, no action at breach is taken. When setting this parameter, it is not possible to set -upc, or -upc_burst.
When this parameter is used, the number of entries used per list may become two or four entries. (Note 1)

Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2

Range of value: <kbps> : 0 to 2400000 (0 to 2.4G) (10-decimals).

If 0 to 4 is specified in the case of RP-C and RP-D, the operation is performed by taking the contract band as 4.1[kbit/s].

<Byte> : 0 to 131072 (10-decimals)

[-maxSpecifiesratethe<kbps>maximum[-max_contractratebustband<Byte>]]restriction by kbit/s. Specifies burst size in byte unit. If a value greater than the line speed is set, no action at breach is taken.

When setting this parameter, it is not possible to set -upc, or -upc_burst.

Packets exceeding the maximum band when setting this parameter are all discarded.

When this is used, the number of entries used per list may become two or four entries.(Note 1)

Default:

None. (No contract band surveillance is executed.)

Range of value: <kbps> : 0 to 2400000 (0 to 2.4G) (10-decimals).

If 0 to11 is specified in the case of RP-A, the operation is performed by taking the contract band as 12[kbit/s].

If 0 to 4 is specified in the case of RP-C and RP-D, the operation is performed by taking the contract band as 4.1[kbit/s].

<Byte> : 0 to 131072 (10-decimals)

[-minSpecifiesratethe<kbps>minimum[-min_bandrateassurancebust<Byte>]]by kbit/s. Specifies burst size in byte unit.

Default: None. (No contract band surveillance is executed.)

Range of value: <kbps>: 0 to 2400000 (0 to 2.4G) (10-decimals).

[-indexSpecifies<No.the>]connection branching index number (index specified in the DLCI group information or the Vc-Group information). It selects and transmits DLCI/ VC specified in the group when relaying the packet that agrees with the flow detecting conditions. For the list information setting the connection branching index number, specify out (Outbound) as the flow control of the output side.

Default: None.

Range of value: 0 to 7.

1-94

GR2K-GA-0014

 

Ver. 07-02