Hitachi GR2000 Series manual Upper Upper limit of the IP user data length is designated

Models: GR2000 Series

1 500
Download 500 pages 15.25 Kb
Page 73
Image 73

 

Filtering/QoS Information

 

 

Default:

None (DSCP values are not included in the flow detecting

 

condition.)

Range of value:

0 to 63 (decimal).

[precedence<precedenceThisValue>]parameter specifies precedence value, which is the upper 3 bits of the ToS field. This is compared to the upper 3 bits of the ToS field of sent/received packets. The lower 5 bits of the ToS field are ignored.

27

26

25

24

23

22

21

20

 

 

 

 

DSCP

 

 

 

CU

 

 

High-Order 6 Bits are Designated.

 

 

 

DSCP (Differentiated Services Code Point), CU (Current Unused)

Default:

None (precedence values are not included in the detecting

 

condition)

Range of value:

0 - 7 (decimal)

[{upperDescription:lower}<Length>]Upper limit or lower limit of the IP user data length are designated (Table 1-23).

 

-upper: Upper limit of the IP user data length is designated.

 

-lower: Lower limit of the IP user data length is designated.

default:

None (TOS values are not included in the flow detecting

 

condition.)

Range of value:

0 to 65535 (decimal).

Table 1-23 Relationship between Upper and Lower IP User Data Length Llimits and IP User Data

 

Relationship between A (Packet Value):

 

Upper and Lower

(Total Length) - (Header Length) and B (IP user data

Result

Limits Designation

length designated in constituting definition

 

 

information)

 

 

 

 

-upper

A < B

Agreed

 

 

 

-upper

A > B

Disagreed

 

 

 

-lower

A > B

Agreed

 

 

 

-lower

A < B

Disagreed

 

 

 