Operation Management Information

Table 4-5 List of Initial Value Items that Can Be Set Using line Information (WAN OC-POS) and Initial Values during Initial Installation

Information

Information Name

Initial Value

Group Name

 

 

 

 

 

line Information

Selection of synchronized clocks in

Synchronized with the clock in a local router.

(WAN

oc3pos

(independent)

OC-POS)

 

 

Multi-CRC length in oc3pos

16 (bits)

 

 

 

 

 

Selection of scramble disable/enable in

Disable (oc3pos_scramble_off)

 

oc3pos

 

 

 

 

 

Setting value of SONET overhead in

Refer to GR2000 Configuration Commands, (universal

 

oc3pos

CLI) Vol. 1, Setting Contents of SONET Overhead for

 

 

the CF010000 (hexadecimal) value.

 

 

 

 

Selection of synchronized clocks in

Synchronized with the clock in a local router.

 

oc12pos

(independent)

 

 

 

 

Multi-CRC length in oc12pos

16 (bits)

 

 

 

 

Selection of scramble disable/enable in

Disable (oc12pos_scramble_off)

 

oc12pos

 

 

 

 

 

Setting value of SONET overhead in

Refer to GR2000 Configuration Commands, (universal

 

oc12pos

CLI) Vol. 1, Setting Contents of SONET Overhead for

 

 

the CF010000 (hexadecimal) value.

 

 

 

 

Selection of synchronized clocks in

Synchronized with the clock in a local router.

 

oc48pos

(independent)

 

 

 

 

Multi-CRC length in oc48pos

16 (bits)

 

 

 

 

Selection of scramble disable/enable in

Disable (oc48pos_scramble_off)

 

oc48pos

 

 

 

 

 

Setting value of SONET overhead in

Refer to GR2000 Configuration Commands, (universal

 

oc48pos

CLI) Vol. 1, Setting Contents of SONET Overhead for

 

 

the CF010000 (hexadecimal) value.

 

 

 

 

Line operating mode in oc48POS

Sonet

 

 

 

 

APS mode in oc48POS

APS is not used. (oc48pos_aps_off)

 

 

 

 

APS return waiting time in oc48POS

300 (seconds)

 

 

 

 

APS protocol type in oc48POS

JT-G783 Annex B (jt_g783_annex_b)

 

 

 

 

APS switchover direction in oc48POS

Bidirectional switching (oc48pos_bidirectional)

 

 

 

 

APS return mode in oc48POS

Non-return mode (oc48pos_non_revertive)

 

 

 

 

SD BER threshold value in oc48POS

6

 

 

 

 

SD BER threshold value in oc48POS

3

 

 

 

GR2K-GA-0014

4-39

Ver. 07-02

 

Page 369