SNMP Information

-intervalDescription:<Seconds>Sets the interval of time in seconds for checking out the alarm

 

threshold. This parameter corresponds to alarmInterval of

 

RFC1757.

Default:

Undefined (but cannot be omitted for the first time)

Range of value:

1-4294967295

-sampleDescription:type{deltaSetsabsolutethe method}for checking out the alarm threshold. The

 

delta option compares the threshold number of packets with

 

the differences between the current samples and the previous

 

samples. The absolute option compares the threshold number

 

of packets directly with the current samples. This parameter

 

corresponds to alarmSampleType of RFC1757.

Default:

Undefined (but cannot be omitted for the first time)

Range of value:

delta or absolute

-startupDescription:alarm{risingSets fallingthe alarmthresholdrisingforfallingRMON}startup alarm. The rising option causes an alarm if the first sampling exceeds the rising (upper-limit) threshold number of packets. The falling option causes an alarm if the first sampling falls short of the falling (lower-limit) threshold number of packets. The rising_falling option causes an alarm if the first sampling exceeds the rising threshold or falls short of the falling threshold. This parameter corresponds to alarmstartUpAlarm of RFC1757.

Default:

.

 

Range of value:

or

-falling

-risingDescription:threshold<Value>Sets the rising threshold number of packets for RMON alarm

 

other than startup. This parameter corresponds to

 

alarmRisingThreshold of RFC1757.

Default:

Undefined (but cannot be omitted for the first time)

Range of value:

1-4294967295

Description:

Sets the index number for an RMON event-group entry

-risingeventindex

exceeding<Number>the rising threshold. Such index number must be

 

equal to the RMON event-group index number defined by the

 

event object. When no ID number has been defined, an alarm

 

not issued. This parameter corresponds to

 

alarmRisingEventIndex of RFC1757.

Default:

rising,Undefined_falling(but cannot be omitted for the first time).

Range of value:

1-65535

GR2K-GA-0014

3-13

Ver. 07-02

 

Page 321
Image 321
Hitachi GR2000 Series Threshold. This parameter corresponds to alarmInterval, Corresponds to alarmSampleType of RFC1757