Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2

5.1Common

Table 5-1 Configuration Error Messages

Message

Contents

 

 

Can not execute config command, please try

Communication error occurred between processes.Wait for recovery,

again.

then execute again.

Command incomplete because processing

Because processing deletion of configuration is taking too much

configuration deletion exceeded time limit.To

time, command is interrupted.Execute same command again.

complete deletion, please try same command

For example, if this message is displayed during the deletion of line

again.

information, the IP information and line information may not have

 

been deleted even if the IP routing protocol has been removed.

Configuration file is closed.

Current or spare configuration file closed.After opening current or

 

spare configuration file, execute configuration command again.

illegal option -- <Option>

Illegal option entered. Correct the option.

Interface name not found.

Specified interface name not found. Specify a correct interface

 

name.

Invalid subcommand.

Subcommand invalid. Enter a correct subcommand.

<item> is not in range <value1> to <value2>.

The value is out of range. Set the in-range value.

 

<item>Parameter name, <value1> Minimum value,

 

<value2>Maximum value

Logical inconsistency occurred.

An internal program complication has occurred in editing and

 

processing the configuration defining information. Collect the

 

following log information and deliver it to the maintenance person.

 

The maintenance person will send the log information to the assisting

 

department.

 

[Procedure to collect log information]

 

1. Set the terminal so that the screen logs can be collected.

 

2. Execute the following commands.

 

(1) cat/var/tmp/gen/genTrace_config

 

(2) cat/var/tmp/gen/genTrace_configManager

 

(3) /usr/local/diag/configShowBinary

 

3. Finish collecting the screen logs.

Maximum number of entries are already

Attempt made to add entries exceeding the limit. Delete unnecessary

defined.

entries, then add an entry.

No enough parameters.

The parameters are insufficient. Specify the necessary parameters.

No such delete index

Because the entered value is illegal, configuration information cannot

 

be deleted. Enter a correct value.

No such insert index

Because the entered value is illegal, configuration information cannot

 

be inserted. Enter a correct value.

No such <object>

The configuration defining information for the name designated in the

 

<object> is not available. Designate the name of the defining

 

information being set.

Now another user configured, please try

Another user is currently changing the configuration. Wait for access,

again.

then execute again.

Now configuration data is changing, please try

Configuration information being changed. Wait for the change, then

again.

execute again.

Now configuration file is locked, please try

The operating configuration defining information cannot be edited

again.

because another user is referencing it using the command.

 

If "more" is displayed in the operation command that indicates the

 

interface name, finish the "more" display, and execute the command

 

again. If “more” is not displayed, execute it again after a while.

Operation not permitted

Because operation configuration information written in memory is

 

being edited, operation is not permitted.

option requires an argument -- <Option>

Option entry insufficient. Correct the option.

 

 

5-2

GR2K-GA-0014

 

Ver. 07-02

Page 392
Image 392
Hitachi GR2000 Series manual Common, Configuration Error Messages, Message Contents