Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2

Table 1-86 UPC Penalty Operation

 

Default Operation

Change Method

 

 

 

Maximum band limitation

Drop

Cannot be changed.

 

(Important)

 

 

 

 

 

 

Maximum band limitation

Drop

Cannot be changed.

(Normal)

 

 

 

 

 

 

Minimum band guarantee

-modified_discard_class 1 *1

Specified by -modified_discard_class

(Important)

 

<No.>.

 

 

 

Minimum band limitation

-modified_discard_class 1 *1

Specified by -modified_discard_class

(Normal)

 

<No.>. *2

 

 

 

 

*1: -modified_priority_class uses the class specified by -priority_class.

*2: Uses -modified_discard_class <No.> set in a minimum band guarantee (important) list.

Change it with the list to be changed not registered in qos-ip-list-group when changing this parameter.

The flow control parameter below uses the setting value specified in an important

￿packet when a normal packet is specified in this parameter.

This parameter-topsmap,is-priorityvalid onlyclass,in RP--C,discardRP-D,_RPclass,-C6,-RPreplace-D6, RPtos,-CV,-upcRP-DV,penalty

GR2000-1B and GR2000-2B.

[upcDescription:groupno<No.>]This parameter sets the same group number in units of groups that control band.

Default:

None (A band is not controlled in units of groups.)

Range of value:

1-2000 (decimal)

A list with the same number operates as an identical band control group when the list in which this parameter is specified set to qos-ip list-group.

This parameter conforms to the conditions below when it is used.

Change it with the list to be changed not registered in qos-ip-list-group when changing this parameter.

The maximum number of lists that can be handled as one group is four.

Set and delete list to and from qos-ip-list-group continuously for each group

￿number in the order below.

This parameter is valid only in RP-C, RP-D, RP-C6, RP-D6, RP-CV, RP-DV, GR2000-1B and GR2000-2B.

1-176

GR2K-GA-0014

 

Ver. 07-02

Page 218
Image 218
Hitachi GR2000 Series manual GR2000-1B and GR2000-2B, Default Operation Change Method