SNMP Information

-intervalDescription:<Seconds>Sets the interval of time in seconds for collecting RMON

 

Ethernet history events. This parameter corresponds to

 

historyControlInterval of RFC1757.

Default:

1800

Range of value:

1-3600

-ownerDescription:<String>

Sets the identification information for the person who created

 

this setting. This parameter corresponds to historyControlOwner

 

of RFC1757.

Default:

Blank

Range of value:

A string of up to 24 alphanumeric and special characters

 

enclosed in double quotation marks. When the string contains

 

only alphanumeric characters and no special characters

 

except period, you can omit double quotation marks. See Table

 

2-1, in GR2000 Configuration Commands, (universal CLI) Vol. 1.

 

for allowable characters.

Example

Create RMON Ethernet history-group control entries and show the resulting history-group control entries in the following order:

1.Using the snmp object with the set subcommand omitted, create an SNMP Manager entry with the following properties:

Community name: public

SNMP Manager IP address: 30.1.1.1

MIB access mode: read/write

2.Using the line object with the set subcommand omitted, set the Ethernet line information with the following properties. (The IP address must be predefined.)

Line name: kyoto

NIF/line number: 0/0

3.Using the line object with the set subcommand omitted, set the Gigabit Ethernet line information with the following properties. (The IP address must be predefined.)

Line name: osaka

NIF/line number: 4/0

4.Using the history-controlobject with the set subcommand omitted, create an RMON Ethernet history-group control entry for the above-mentioned Ethernet line with the following properties:

RMON Ethernet history-group control index number: 33

Interface name: kyoto

Number of history-group entries: 10

￿Owner: “net-mgr ken”

5.Using the history-controlobject with the set subcommand omitted, set the RMON Ethernet history-group control entry for the above-mentioned Gigabit Ethernet line with the following properties: