Undefined (but cannot be omitted for the first time)
Default:

Hitachi Gigabit Router GR2000 Series Enhanced Version Configuration Commands, Vol. 2

-fallingDescription:threshold<Value>Sets the falling threshold number of packets for RMON alarm other than startup. This parameter corresponds to alarmFallingThreshold of RFC1757.

Range of value: 1-4294967294

-fallingDescription:event_indexSets<Number>the index number for an RMON event-group entry falling

 

short of the falling threshold. Such index number must be

 

equal to the RMON event-group index number defined by the

 

event object. When no ID number has been defined, an alarm

 

is not issued. This parameter corresponds to

 

alarmFallingEventIndex of RFC1757.

Default:

Undefined (but cannot be omitted for the first time)

Range of value:

1-65535

-ownerDescription:<String>

Sets the identification information for the person who created

 

this setting. This parameter corresponds to alarmOwner of

 

RFC1757.

Default:

Blank

Range of value: A string of up to 24 alphanumeric and special characters enclosed in double quotation marks. When the string contains only alphanumeric characters and no special characters except period, you can omit double quotation marks. See Table 2-1, in GR2000 Configuration Commands, (universal CLI) Vol. 1 for allowable characters.

Example

Create RMON Ethernet alarm-group entries and show the resulting alarm-group entries the following order:

1.Using the snmp object with the set subcommand omitted, create an SNMP Manager entry with the following properties:

Community name: public

SNMP Manager IP address: 30.1.1.1

MIB access mode: read/write

Trap option: trap

2.Using the event object with the set subcommand omitted, create an event-group entry with the following properties:

RMON Ethernet event-group index number: 3

Event type: log_trap

Trap community name: public

3.Using the alarm object with the set subcommand omitted, create an RMON Ethernet alarm-group entry with the following properties for the above ￿event-group entry:

RMON Ethernet alarm-group index number: 12

3-14

GR2K-GA-0014

 

Ver. 07-02

Page 322
Image 322
Hitachi GR2000 Series manual Short of the falling threshold. Such index number must be, AlarmFallingEventIndex of RFC1757