Filtering/QoS Information

{ in out }

Inbound/Outbound is designated. Either one or both of the Inbound/Outbound can be set simultaneously.

in :Inbound (Designation of frame input side)

out:Outbound (Designation of frame output side)

Default:

No default is possible.

[-disable]

The flow control is nullified by each input/output interface.

 

 

Default:

No default is possible.

 

list <List No.>

 

 

 

The list numbers are designated.

 

 

Default:

Default is possible only for the case of indication. All the lists

 

 

 

are indicated at default.

 

 

Range of value:

IPv4 filter list: 1 to 20000 (decimal)

 

[list <List No.>-list <list No.>]

 

 

Description:

Specifies the range of a list number. This parameter can be

 

 

 

specified only when a blank list number is displayed.

 

 

Default:

The range of the list number to be displayed corresponds to all

 

 

 

list numbers.

 

 

Range of value:

IPv4 filter list: 1 to 20000 (Decimal)

 

 

 

IPv6 filter list: 40001 to 60000 (Decimal)

 

free

 

 

 

 

Description:

Displays the blank list number.

 

 

Default:

Cannot be omitted when the blank list number is displayed.

 

min_no

 

 

 

Description:

Displays the top blank list number in the specified range.

 

 

Default:

Cannot be omitted when the top list number of a blank list

 

 

 

number is displayed.

 

 

Flow detecting condition parameter

 

{ ip <protocol No.> tcp udp icmp igmp }

 

 

Description:

The high-order protocol numbers or protocol names are

 

 

 

designated. If all protocols are taken as the object, IP is

 

 

 

designated.

 

 

 

In case of IPv4 filter list, icmp6 cannot be designated. In case

 

 

 

of IPv6 filter list, icmp and igmp cannot be designated.

 

 

Default:

No default is possible.

 

 

Range of value:

0 to 255 (decimal). (Please refer to Table 1-22.)

 

 

 

GR2K-GA-0014

 

1-29

Ver. 07-02

￿

 

 

Page 71
Image 71
Hitachi GR2000 Series manual Filtering/QoS Information