Hitachi GR2000 Series manual Operation Management Information Parameters, GFR2

Models: GR2000 Series

1 500
Download 500 pages 15.25 Kb
Page 377
Image 377

Operation Management Information

Parameters

The initial value items that can be set using ATM Information and the initial values during initial installation are shown in Table 4-11.

Table 4-11 List of Initial Values That Can Be Set Using ARM Information and Initial Values During Initial Installation

Information

Information Name

Initial Value

Group Name

 

 

 

 

 

ATM

Setting range of VPI and VCI values

3 (VPI=0-63,

information

 

CVCI=32-511)

 

 

 

 

Setting of maximum VP count

64

 

 

 

 

Setting of service category pattern

cbr_cbr_ubr_ubr

 

 

 

Traffic

Setting of cell transmission priority in CBR

2

information

 

 

Setting of cell transmission priority in ABR

2

 

 

 

 

Setting of mcr value in ABR

38kbps

 

 

 

 

Setting of icr value in ABR

38kbps

 

 

 

 

Setting of cell transmission priority in UBR

4

 

 

 

 

Setting of MBS value in VBR

30

 

 

 

 

Discard threshold of non-priority packet (CLP1) in GFR

1000cells

 

 

 

 

Discard threshold of priority packet (CLP0) in GFR

1500cells

 

 

 

 

Setting of cell transmission priority in GFR

3

 

 

 

 

pcr value of highest priority packet in GFR2

250kbps

 

 

 

 

Priority frame discard threshold of highest priority queue in GFR2

700cells

 

 

 

 

Non-priority frame discard threshold of highest priority queue in

500cells

 

GFR2

 

 

 

 

 

Priority frame discard threshold of high priority queue in GFR2

700cells

 

 

 

 

Non-priority frame discard threshold of high priority queue in

500cells

 

GFR2

 

 

 

 

 

Priority frame discard threshold of middle priority queue in GFR2

700cells

 

 

 

 

Non-priority frame discard threshold of middle priority queue in

500cells

 

GFR2

 

 

 

 

 

Priority frame discard threshold of low priority queue in GFR2

700cells

 

 

 

 

Non-priority frame discard threshold of low priority queue in

500cells

 

GFR2

 

 

 

 

 

Setting of cell transmission priority in GFR2

3

 

 

 

VP information

VP warning and loop-back function

A VP warning and

 

 

loop-back function

 

 

are used.

 

 

 

GR2K-GA-0014

4-47

Ver. 07-02

 

Page 377
Image 377